ASCO Model 130 (Edco PB Series) Surge Protective Device

The ASCO Model 130 modules are solid-state protectors for Intercom Extension Pairs. These hybrid protectors are intended to be used in conjunction with the ASCO MGBW ground rail and a standard M1- 50 punch down block. The Model 130 modules feature solid-state resettable fuses (PTCs) between the protected equipment and the over voltage clamping components. This unique design prevents problems with “All-Call” in the event of catastrophic protector failure.

Best Suited For
  • Telecom
  • Fire/Alarm/Security
5 Year Warranty
How to buy

Specifications

Specifications per model ASCO Model 130 (Edco PB Series) Surge Protective Device
Previous Model Name Product Type Application Technology Height (in / mm) Width (in / mm) Depth (in / mm) Weight (lbs / kgs)
Edco PB Series Data/Signal Intercom Systems MOV/PTC or SAD/PTC 1.25 in / 31.8 mm 0.40 in / 10.2 mm 2.8 in / 71.1 mm 0.06 lbs / 0.03 kgs
* To view a specific model product page click on the model name above.
ADDITIONAL TECHNICAL SPECIFICATIONS
Voltage/Configuration
12, 56 VDC
Maximum Operating Current
150mA
DC Clamping Voltage
21, 70 VDC
Surge Capacity
0.2, 0.5kA
Connection Type
M1-50 Punch Down Block
Enclosure Type / Rating
Plastic
Certifications
UL 497B
Modes of Protection
L-L

Downloads

Technical Specifications

*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.

Features

Over current protection
Replaces bridging clips on M1-50 bock
UL 497B listed
Utilizes MGB grounding rail
Test point accessible
5-year warranty 

Services & Support

Support

Frequently Asked Questions
Q
How is the ASCO Model 130 series intended to be connected?
A
The 130 series is intended to be used with the MGBW-LUG ground rail and a standard M1-50 punch down block.
Q
What is the maximum operating current of the ASCO Model 130 series?
A
The maximum operating current is 150mA.
Q
What is the intended application of the ASCO Model 130 series?
A
The 130 series is intended to protect call-in circuits (130D021S200SPDN0) or speaker circuits (130D070S500MPDN0).
Q
Is the ASCO Model 130 series UL listed?
A
Yes, the 130 series is listed to UL 497B.

Contacts

Sales In USA Change Location
Liebert Products & Services-Capitol Sales Office
Email Contact +1 703 726 4100 Fax +1 703 729 3837
44611 Guilford Dr Ste 180 Ashburn Virginia 20147
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Monitoring
FRANK PARSONS BUSINESS PRODUCTS
4309 HENNINGER CRT ASHBURN Virginia 20147
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
INTELLIGENT DECISIONS INC
21445 BEAUMEDE CIR ASHBURN Virginia 20147
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
DIGITAL TECHNOLOGIES INC
STE 550 45150 BUSINESS CT STERLING Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
E TEL SYSTEMS CORP
STE 140 43766 TRADE CTR PL DULLES Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
TECHNICA CORP
22970 INDIAN CREEK RD SUITE 500 DULLES Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
ANIXTER - FEDERAL SALES DC METRO
45075 OLD OX RD DULLES INTERNATIONAL Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
GRAYBAR ELECTRIC VENDOR#3667102
45145 OCEAN COURT STERLING Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), DC Power Systems, Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
WESCO DISTRIBUTION
STE 145 45449 SEVERN WAY STERLING Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
DULLES ELECTRIC SUPPLY CORP
22570 SHAW RD STE 150 STERLING Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
Support Change Location
Vertiv - Surge Protective Devices Support
14550 58th Street North Clearwater Florida 33760 USA
Product areas of focus: Surge Protective Devices

LATEST INDUSTRY TRENDS, TECHNOLOGIES AND SOLUTIONS

Unified Infrastructure

App-first: Simplicity for Customers, Complexity for IT

Mobile devices have fast become the most important screen for consumers, to the point that firefighters are weighing in on our digital addictions.

March 21, 2017
Data Center/Colocation/Hosting

How Does "Mission-Critical" Translate In the Digital Economy?

I vaguely remember when I first came across the concept of the data center. In fact, it was the discovery of a seemingly obscure and futuristic sounding thing called a ‘mainframe’.

March 17, 2017
;