Performance Optimization Services

Arc Flash Studies

Arc flash incidents are highly concentrated radiant thermal energy resulting from an arcing fault between two points. These potentially devastating events kill or injure people every day. An up-to-date arc flash study helps mitigate these hazards by calculating the limited and restricted approach boundaries inside which workers must use appropriate personal protective equipment (PPE).

Ensuring safety and meeting regulatory requirements can be difficult to accomplish in-house without the assistance of resources familiar with industry standards and recommended practices. Vertiv’s NETA-certified technicians receive ongoing education and adhere to strict standards in safety and electrical testing knowledge when performing an arc flash study.

Best Suited For
  • Data Center/Colocation/Hosting
  • Healthcare
  • Manufacturing
  • Oil and Gas
  • Power Generation
  • Power/Gas Transmission and Distribution

Features

...
Data collection includes critical equipment information that is necessary to perform accurate arc flash hazard analysis
Arc flash calculations are performed with state-of-the-art software and in accordance with the standards of NFPA and IEEE
Comprehensive reporting, including the results of the hazard analysis and expert recommendations, helps ensure compliance with OSHA and NFPA standards

Benefits

...
Improved regulatory compliance results from performing arc flash hazard analysis in accordance with industry guidelines 
Improved worker safety is achieved by identifying potential hazards and implementing recommendations to mitigate risk 
Greater productivity occurs by reducing business disruption and lost man hours that can result from arc flash incidents 
Enhanced system performance results from improved maintenance practices and preventing equipment damage 

Support

Frequently Asked Questions
Q
What is an arcing fault?
A
An arcing fault is the flow of current through the air between phase conductors or phase conductors and neutral or ground.
Q
What causes an electrical arc?
A
An arc occurs when electric current flows between two or more separated energized conducting surfaces. Some arcs are caused by human error including dropped tools, accidental contact with electrical systems, and improper work procedures. Another common cause of an arc is insulation failure.
Q
What can happen if I am exposed to arc flash?
A
Exposure to an arc flash frequently results in a variety of serious injuries, and in some cases, death. Workers have been injured even though they were 10 feet or more away from the arc center.
Q
What can I do to reduce my risk to arc flash exposure?
A
Preventive maintenance, worker training, and an effective safety program can significantly reduce arc flash exposure.
Q
Are all arcs equal?
A
No. You must conduct a hazard assessment to determine the level (intensity) of energy from the arc in calories. Then you can determine the proper personal protective equipment (PPE) needed.

Contacts

Sales In USA Change Location
FEDBIZ IT SOLUTIONS LLC
305 HARRISON STREET SE STE 1C LEESBURG Virginia 20175
Service areas of focus:
GHA TECHNOLOGIES
407 HANRAHAN CT SE LEESBURG Virginia 20175
Service areas of focus:
ADAR INC
16182 HILLSBORO RD PURCELLVILLE Virginia 20132
Service areas of focus:
FRANK PARSONS BUSINESS PRODUCTS
4309 HENNINGER CRT ASHBURN Virginia 20147
Service areas of focus:
INTELLIGENT DECISIONS INC
21445 BEAUMEDE CIR ASHBURN Virginia 20147
Service areas of focus:
Liebert Products & Services-Capitol Sales Office
Email Contact +1 703 726 4100 Fax +1 703 729 3837
44611 Guilford Dr Ste 180 Ashburn Virginia 20147
Service areas of focus:
ANIXTER - FEDERAL SALES DC METRO
45075 OLD OX RD DULLES INTERNATIONAL Virginia 20166
Service areas of focus:
DIGITAL TECHNOLOGIES INC
STE 550 45150 BUSINESS CT STERLING Virginia 20166
Service areas of focus:
DULLES ELECTRIC SUPPLY CORP
22570 SHAW RD STE 150 STERLING Virginia 20166
Service areas of focus:
E TEL SYSTEMS CORP
STE 140 43766 TRADE CTR PL DULLES Virginia 20166
Service areas of focus:
Support Change Location
ASCO Services, Inc.
50 Hanover Road Florham Park New Jersey 07932
Service areas of focus:
VERTIV (Chloride)
Email Contact +1 713 934 5100 Fax +1 713 934 5195
5980 West Sam Houston Parkway North, Suite 100 Houston Texas 77041
Service areas of focus:
IT Solutions (Support)
Service areas of focus:
VERTIV (Energy Systems - Account Management)
Service areas of focus:
VERTIV (Energy Systems - DC Power Depot Repair)
Service areas of focus:
VERTIV (Energy Systems - DC Power Product Training)
Service areas of focus:
VERTIV (Energy Systems - DC Power Technical Support)
Service areas of focus:
VERTIV (Energy Systems - Installation & After Market Services)
Service areas of focus:
VERTIV (Energy Systems - Outside Plant Technical Support)
Service areas of focus:
VERTIV (Energy Systems - Spare Parts)
Service areas of focus:

LATEST INDUSTRY TRENDS, TECHNOLOGIES AND SOLUTIONS

Facility Optimization

What is a Single-Line Diagram?

The single-line diagram is the blueprint for electrical system analysis.

November 28, 2016
DCIM & IT Management

Return on Investment

May 30, 2016
DCIM & IT Management

Is Your Organization Ready?

May 30, 2016
Facility Optimization

What Causes "Dirty" Power?

Whether it's called a surge, a sag, a spike, a transient, a fluctuation, an interruption, or noise, "dirty power" is some type of abnormality in the electricity that runs your facility.

September 14, 2016