Software

Trellis™ Thermal System Manager

Provides thermal management for the dynamic and often complex data center environment.​​​​​

Best Suited For
  • Banking, Financial and Insurance
  • Data Center/Colocation/Hosting
  • Education
  • Government
  • Healthcare
  • Retail and Wholesale
  • Telecom

Specifications

Workstation Requirements Operating System: • Microsoft® Windows® 7 • Microsoft® Windows® 2008 • Red Hat® Enterprise Linux version 5.6 or higher Hardware Requirements: • Dual-core Intel® Pentium® 4 CPU at 2.8 GHz • 8 GB RAM, LAN connection Additional software: • Adobe® Flash® Player version 12 or higher • Microsoft® Word 2007 or higher • Notepad++ • Microsoft® RDP Client (if installing the Trellis™ platform on Windows®) • PuTTY (if installing the Trellis™ platform on Linux® or configuring the Avocent® Universal Management Gateway appliance) • WinSCP (if installing the Trellis™ platform on Linux®) Browsers for the Trellis™ platform user interface: • Mozilla® Firefox® version 31.0 or higher • Google Chrome™ version 40.0 or higher • Microsoft Internet Explorer® 9 and 10 with standard mode (compatibility mode is off) and 11 Browsers for the symbol portal: • Microsoft Internet Explorer® 9 and 10 (with compatibility mode on) and 11 Browsers for 3D features: • Microsoft Internet Explorer® 11, Chrome and Firefox Server Requirements Hardware Recommendations: Data Size Guidelines Small Medium Large Enterprise Concurrent users 10 20 50 100 Devices 2,000 20,000 100,000 200,000 Power Connections 1,000 10,000 60,000 100,000 Data Connections 2,000 10,000 60,000 100,000 Monitored Datapoints 1,000 10,000 40,000 140,000 Front Machine Small Medium Large Enterprise Processor Intel® Xeon® 2.6 GHz 8M L3 cache CPU count 1 2 2 2 CPU cores 4 4 4 8 Memory (GB) DDR3 1333 MHz 32 32 40 44 Disk throughput > 500 MB/s (sequential) [un-cached] Storage 300 GB Enterprise class Ethernet > 80 MB/s Back Machine Small Medium Large Enterprise Processor Intel® Xeon® 2.6 GHz 8M L3 cache CPU count 1 2 2 2 CPU cores 4 4 4 8 Memory (GB) DDR3 1333 MHz 24 32 32 32 Disk throughput > 500 MB/s (sequential) [noncached] Storage *300 GB Enterprise class for base installation Ethernet > 80 MB/s

Specifications per model Trellis™ Thermal System Manager
Processor Server Operating System Supported Browsers Version
Front Machine - Intel® Xeon® 2.6 GHz 8M L3 cache; Back Machine Intel® Xeon® 2.6 GHz 8M L3 cache Microsoft® Windows® 2008, R2 SP1 Enterprise, 64-bit (full installation); Red Hat® Enterprise Linux® version 6.4, 6.5 or 6.6, 64-bit Mozilla® Firefox® version 31.0 or higher; Google Chrome™ version 40.0 or higher; Microsoft Internet Explorer® 9 and 10 with standard mode and 11 4.0.2
* To view a specific model product page click on the model name above.
ADDITIONAL TECHNICAL SPECIFICATIONS
Monitored Data Points
Organization Size: Small - 1,000; Medium - 10,000; Large - 40,000; Enterprise - 140,000
CPU Manufacturer
Intel® Xeon®
CPU count
Front and Back Machines: Small - 1; Medium - 2; Large - 2; Enterprise - 2
CPU Cores
Front and Back Machines: Small - 4; Medium - 4; Large - 4; Enterprise - 8
Memory (GB)
Front Machine: Small - 32; Medium - 32; Large - 40; Enterprise - 44 Back Machine: Small - 24; Medium - 32; Large - 32; Enterprise - 32
Storage
Front and Back Machines: 300GB Enterprise class
Ethernet
Front and Back Machines: >80 MB/s

Features

...
Balance the available cooling capacity between IT devices and the facility
Predict thermal capacity that balances total cooling production with the actual heat load at the room and rack level
Understand the true thermal capacity for planning and redundancy, so as to reduce wasteful overcooling to lower energy cost
Monitor rack level details and compare the temperature profile and heat load for each rack
Bridge the gap between facilities and IT and manage your cooling chain from the mechanical system, rack, down to server
Monitor and set threshold alarms for the service processor temperature inside critical IT devices for an added level of protection 

Benefits

...
 Track thermal improvements over time and document results
Alarm management, notification, and thresholds for environmental sensors
Optimize cooling temperatures to lower cooling energy costs
Rack level metrics to balance cooling and the IT heat load
Manage cooling units and optimized based on performance and efficiency
View IT service processor information for added protection against downtime
Monitor the cooling system and how it impacts my day to day operations
Monitor and analyze capacity to determine utilization, efficiency, and future planning

Contacts

Sales In USA Change Location
FEDBIZ IT SOLUTIONS LLC
305 HARRISON STREET SE STE 1C LEESBURG Virginia 20175
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
GHA TECHNOLOGIES
407 HANRAHAN CT SE LEESBURG Virginia 20175
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
ADAR INC
16182 HILLSBORO RD PURCELLVILLE Virginia 20132
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
FRANK PARSONS BUSINESS PRODUCTS
4309 HENNINGER CRT ASHBURN Virginia 20147
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
INTELLIGENT DECISIONS INC
21445 BEAUMEDE CIR ASHBURN Virginia 20147
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
ANIXTER - FEDERAL SALES DC METRO
45075 OLD OX RD DULLES INTERNATIONAL Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
DIGITAL TECHNOLOGIES INC
STE 550 45150 BUSINESS CT STERLING Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
DULLES ELECTRIC SUPPLY CORP
22570 SHAW RD STE 150 STERLING Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
E TEL SYSTEMS CORP
STE 140 43766 TRADE CTR PL DULLES Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
GRAYBAR ELECTRIC VENDOR#3667102
45145 OCEAN COURT STERLING Virginia 20166
Product areas of focus: Uninterruptible Power Supplies (UPS), DC Power Systems, Power Distribution, Surge Protective Devices, Thermal Management, Integrated Solutions, Racks and Containment, Software, IT Management, Monitoring
Support Change Location
IT Solutions (Support)
Product areas of focus: Software, IT Management, Monitoring

LATEST INDUSTRY TRENDS, TECHNOLOGIES AND SOLUTIONS

DCIM & IT Management

Network Infrastructure Management Solution

Avocent’s Network Infrastructure Management Solution delivers unmatched serial console and remote access to multiple system consoles. No matter how spread out your WAN is. No matter what all you have stuffed on it.

November 24, 2016

Trellis™ Enterprise and Quick Start Solutions Software Downloads

New customers will require a Professional Services engagement contract to perform a full installation of the Trellis™ Platform.

October 24, 2016